Digital Multimeter Fluke117C

Call for Price

Compare
Category:

Description

Features:
VoltAlert™ technology for non-contact voltage detection
AutoVolt automatic AC/DC voltage selection
Low input impedance: helps prevent false readings due to ghost voltage
Large white LED backlight to work in poorly lit areas
True RMS for accurate measurements on non-linear loads
Measures 10 A (20 A overload for 30-seconds)
Resistance, continuity, frequency and capacitance
Min/Max/Average with elapsed time to record signal fluctuations
Compact ergonomic design for one-handed operation
Compatible with optional magnetic hanger (ToolPak™) for hands free operation
CAT III 600 V safety rated

Specifications:
Maximum voltage between any terminal and earth ground :600 V
Surge protection :6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2
Fuse for A input :11 A, 1000 V FAST Fuse (Fluke PN 803293)
Display :Digital: 6,000 counts, updates 4 per second
Bar graph :33 segments, updates 32 per second
Operating Temperature :-10 °C to + 50 °C
Storage Temperature : -40 °C to + 60 °C
Battery type :9 volt Alkaline, NEDA 1604A/ IEC 6LR61
Battery Life :400 hours typical, without backlight
Accuracy Specifications
DC millivolts
Range: 600.0 mV
Resolution: 0.1 mV
Accuracy: ± ([% of reading] + [counts]): 0.5% + 2
DC volts
Range/Resolution: 6.000 V / 0.001 V
Range/Resolution: 60.00 V / 0.01 V
Range/Resolution: 600.00 V / 0.1 V
Accuracy: ± ([% of reading] + [counts]): 0.5% + 2
Auto volts
Range: 600.0 V
Resolution: 0.1 V
Accuracy: 2.0 % + 3 (dc, 45 Hz to 500 Hz)
4.0 % + 3 (500 Hz to 1 kHz)
AC millivolts1 true-rms
Range: 600.0 mV
Resolution: 0.1 mV
Accuracy: 1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
AC volts1 true-rms
Range/Resolution: 6.000 V / 0.001 V
Range/Resolution: 60.00 V / 0.01 V
Range/Resolution: 600.0 V / 0.1 V
Accuracy: 1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
Continuity
Range: 600 O
Resolution: 1 O
Accuracy: Beeper on less than 20 O , off more than 250 O ; detects opens or shorts of 500 µs or longer.
Ohms
Range/Resolution: 600.0 O / 0.1 O
Range/Resolution: 6.000 k O / 0.001 k O
Range/Resolution: 60.00 k O / 0.01 k O
Range/Resolution: 600.0 k O / 0.1 k O
Range/Resolution: 6.000 M O / 0.001 M O
Accuracy: 0.9 % + 1
Range/Resolution: 40.00 M O / 0.01 M O
Accuracy: 5 % + 2
Diode Test
Range/Resolution: 2.000 V / 0.001 V
Accuracy: 0.9% + 2
Capacitance
Range/Resolution: 1000 nF / 1 nF
Range/Resolution: 10.00 µF / 0.01 µF
Range/Resolution: 100.0 µF / 0.1 µF
Range/Resolution: 9999 µF / 1 µF
Range/Resolution: 100 µF to 1000 µF
Accuracy: 1.9% + 2
Range/Resolution: > 1000 µF
Accuracy: 5% + 20%
LoZ capacitance
Range: 1 nF to 500 µF
Accuracy: 10% + 2 typical
AC amps true-rms (45 Hz to 500 Hz)
Range/Resolution: 6.000 A / 0.001 A
Range/Resolution: 10.00 A / 0.01 A
Accuracy: 1.5% + 3
20 A continuous overload for 30 seconds max
DC amps
Range/Resolution: 6.000 A / 0.001 A
Range/Resolution: 10.00 A / 0.01 A
Accuracy: 1.0% + 3
20 A continuous overload for 30 seconds max
Hz (V or A input)2
Range/Resolution: 99.99 Hz / 0.01 Hz
Range/Resolution: 999.99 Hz / 0.1 Hz
Range/Resolution: 9.999 Hz / 0.001 Hz
Range/Resolution: 50.00 Hz / 0.01 Hz
Accuracy: 0.1% + 2

Reviews

There are no reviews yet.

Be the first to review “Digital Multimeter Fluke117C”

Your email address will not be published. Required fields are marked *


Notice: Trying to access array offset on value of type bool in /home/u844851292/domains/icmasteronline.com/public_html/wp-content/plugins/premmerce-search/views/frontend/autocomplete-template.php on line 9

Notice: Trying to access array offset on value of type bool in /home/u844851292/domains/icmasteronline.com/public_html/wp-content/plugins/premmerce-search/views/frontend/autocomplete-template.php on line 21

Notice: Trying to access array offset on value of type bool in /home/u844851292/domains/icmasteronline.com/public_html/wp-content/plugins/premmerce-search/views/frontend/autocomplete-template.php on line 30
All search results
X